Zoning · Brampton · Residential

R3D zone, Brampton: Residential Townhouse D-x

Section 16.9 of the City of Brampton Zoning By-law 270-2004, as amended by 48-2006, 220-2006, 238-2007, 204-2010, 233-2010, 253-2021.

A street townhouse zone where the number after "R3D-" on the zoning map sets the minimum lot width for each interior unit, with lot area, garage size and driveway rules tied to that width.

Is a property in the R3D zone? Enter its address and the lookup returns the zone and these standards, including any site-specific exception.

Check an address

What the R3D zone permits

  • A street townhouse dwelling
  • Supportive housing residence type 1
  • A place of worship
  • Purposes accessory to the other permitted purposes

Standards

RequirementBy-law
Minimum lot area (interior lot)See noteMinimum lot area per dwelling unit shall be 30 times the minimum lot width, in square metres
Minimum lot width (interior lot)See noteInterior lot: the numerical number following the zoning symbol R3D- on Schedule A is the minimum interior lot width in metres (e.g. R3D-6 = 6 m)
Minimum lot width (corner lot)See noteCorner lot: the dwelling unit closest to the flankage lot line shall have a minimum lot width 1.8 m more than the minimum interior lot width
Minimum lot depth30 m
Minimum front yard4.5 m4.5 m, but 6.0 m to the front of the garage
Minimum interior side yard1.2 m
Minimum exterior side yard3 m
Minimum rear yard7.5 m
Maximum building height10.6 m
Minimum landscaped open spaceSee noteThe entire yard areas shall be landscaped open space other than a driveway, an encroachment, or an accessory building permitted by this by-law
Minimum unit width6 m

Other provisions in this section

  • Zone symbol suffix -x (e.g. R3D-6, R3D-6.1, R3D-7.5 on Schedule A) is the minimum interior lot width in metres (Section 16.9 header).
  • Garage control (k)(1): no garage shall project into the front yard more than 1.5 m beyond a porch or front wall of a dwelling.
  • Garage control (k)(2): no garage shall face the flankage lot line.
  • Garage control (k)(3): maximum cumulative garage door width is 2.5 m if the dwelling unit lot width is less than 8.2 m; 3.1 m if the lot width is 8.2 m or more but less than 9.2 m; 3.7 m if the lot width is 9.2 m or more.
  • Garage control (k)(4): maximum interior garage width shall be 0.6 m wider than the permitted maximum cumulative garage door width.
  • Driveway width (l): the driveway width shall not exceed the width of the garage.
  • Other setbacks (m): when abutting a TransCanada Pipe Line right-of-way the minimum building setback shall be 10 m.
  • Encroachment (n): a balcony or porch may project into the minimum front yard by a maximum of 1.8 m including eaves and cornices.
  • Accessory buildings (o): minimum setback of 0.6 m to a rear yard lot line or an interior side yard lot line.

Source: Section 16.9, By-law 270-2004 (City of Brampton), checked 2026-09-10. General provisions elsewhere in the by-law (parking, driveways, accessory buildings) also apply, and a numbered exception on the parcel can change any value here. Treat this as a pre-check, not a sign-off.

Other residential zones in Brampton: R1A, R1B, R1C, R1D, R1E, R1F, R2A, R2B, R2C, R2D, R2E, R3A, R3B, R3C, R3E, R4A, R4B, RE1, RE2, REH, RH, RHM1, RHM2